Review




Structured Review

Data Spectrum Corporation ultra-micro hot-rods phantom data spectrum
Ultra Micro Hot Rods Phantom Data Spectrum, supplied by Data Spectrum Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/ultra+micro+hot+spot+phantom/pm36961005-94-3-6
Average 90 stars, based on 1 article reviews
ultra-micro hot-rods phantom data spectrum - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Detection and quantification of small and low‐uptake lesions for differentiated thyroid carcinoma using non‐time‐of‐flight iodine‐124 PET/MRI
Article Snippet: To evaluate the lesion detectability and quantification performance, in this study, an abdominal NEMA phantom (Data Spectrum Corporation, Durham, USA) with six small glass spheres was used, which has been described by Kersting et al. recently.

Article Title: Detection and quantification of small and low-uptake lesions for differentiated thyroid carcinoma using non-time-of-flight iodine-124 PET/MRI.
Article Snippet: To evaluate the lesion detectability and quantification performance, in this study, an abdominal NEMA phantom (Data Spectrum Corporation, Durham, USA) with six small glass spheres was used, which has been described by Kersting et al. recently.7 The six spheres had an inner sphere diameter (sphere volume) of 9.7 mm (0.478 mL), 8.9 mm (0.369 mL), 7.7 mm (0.239 mL), 6.5 mm (0.144 mL), 4.8 mm (0.058 mL), and 3.7 mm (0.027 mL).

Article Title: Ultra-High Spatial Resolution Clinical Positron Emission Tomography (PET) Systems
Article Snippet: A micro-Derenzo hot-rod phantom (Data Spectrum Corporation, Durham, NC) was scanned at the center of the FOV, and a separate scan was conducted with the same phantom placed at the edge of the FOV (Figure 9).

Article Title: Robustness of textural analysis features in quantitative 99 m Tc and 177 Lu SPECT-CT phantom acquisitions.
Article Snippet: Data Spectrum Corporation, Greer K. NEMA IEC Body Phantom set: User’s Manual.

Article Title: Characterization of myocardial perfusion imaging systems - an extension of quality metrics.
Article Snippet: Purpose: The aim of this study was to evaluate the performance of myocardial perfusion imaging (MPI) systems in detecting perfusion defects (PDs).. The defect perfusion index (DPI) was introduced to extend and further advance the current MPI quality metrics.. Methods: An anthropomorphic phantom simulating normal and pathological myocardial perfusion conditions was imaged by various NaI-crystal detector systems with and without corrections for scatter (SC) and attenuation (AC) (Symbia, Symbia + SC, Symbia IQ + SCAC, Symbia IQ), and cadmium-zinc-telluride detector systems without corrections (DSPECT, D530c).

Tomography:

Article Title: Optimization and application of renal depth measurement method in the cadmium-zinc-telluride‑based SPECT/CT renal dynamic imaging.
Article Snippet: .. The kidney phantoms were positioned within a Jaszczak phantom (Deluxe ECT Phantom, Model ECT/DLX/P, Data Spectrum Corporation, USA), and lateral scanning and nuclear medicine tomography were performed. ..

Positron Emission Tomography-Computed Tomography:

Article Title: Optimization of penalization function in Bayesian penalized likelihood reconstruction algorithm for [ 18 F]flutemetamol amyloid PET images.
Article Snippet: Point-spread-function (PSF) correction is not recommended for amyloid PET images due to Gibbs artifacts.. Q.ClearTM, a Bayesian Penalized Likelihood (BPL) reconstruction method without incorporating PSF correction reduces these artifacts but degrades image contrast by our previous findings.. The present study aimed to recover lost contrast by optimizing reconstruction parameters in time-of-flight (TOF) BPL reconstruction of amyloid PET images without PSF correction.

Positron Emission Tomography:

Article Title: Concurrent mapping of Electrical, Chemical, and Functional Neuroactivity
Article Snippet: .. We utilized a NEMA image quality phantom (Data Spectrum Corp, NC, USA) to evaluate the impact of EEG electrodes, fNIRS optodes and optical fibers, and the eye tracking mirror on PET image quality collected from PMEEN system (Fig. S4). ..



Similar Products

86
Mendeley Ltd benchtop and phantom testing raw data
Benchtop And Phantom Testing Raw Data, supplied by Mendeley Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/associated+cardiac+data+dataset+diseases+fqrs+in+of+outcomes+pediatric+prognostic+structured+with/pmc12719177-37-0-10
Average 86 stars, based on 1 article reviews
benchtop and phantom testing raw data - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Takeda meg phantom data analysis
Meg Phantom Data Analysis, supplied by Takeda, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/meg+phantom+data+analysis/pm40218576-552-17-10
Average 90 stars, based on 1 article reviews
meg phantom data analysis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry multi-data scanning system water phantom model 90592
Multi Data Scanning System Water Phantom Model 90592, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/smartscan+water+phantom/10__47391_slash_jpma___bagh___16___70-29-1-8
Average 90 stars, based on 1 article reviews
multi-data scanning system water phantom model 90592 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Data Spectrum Corporation ultra-micro hot-rods phantom data spectrum
Ultra Micro Hot Rods Phantom Data Spectrum, supplied by Data Spectrum Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/ultra+micro+hot+spot+phantom/pm36961005-94-3-6
Average 90 stars, based on 1 article reviews
ultra-micro hot-rods phantom data spectrum - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIM Software Inc cirs ct-data–to–electron-density phantom
Cirs Ct Data–To–Electron Density Phantom, supplied by MIM Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/cirs+ct+data+to+electron+density+phantom/pm36215568-59-36-40
Average 90 stars, based on 1 article reviews
cirs ct-data–to–electron-density phantom - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Data Spectrum Corporation abdominal torso nema phantom data spectrum, corporation, durham
Abdominal Torso Nema Phantom Data Spectrum, Corporation, Durham, supplied by Data Spectrum Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/abdominal+torso+nema+phantom+data+spectrum++corporation++durham/pmc10199857-89-4-8
Average 90 stars, based on 1 article reviews
abdominal torso nema phantom data spectrum, corporation, durham - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Siemens Healthineers phantom data
Phantom Data, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/phantom+data/10__1109_slash_tmi__2022__3193132-382-16-11
Average 90 stars, based on 1 article reviews
phantom data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CIRS Inc 3d point-cloud data (1280x720) of human body phantom atom phantom
3d Point Cloud Data (1280x720) Of Human Body Phantom Atom Phantom, supplied by CIRS Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/3d+point+cloud+data++1280x720++of+human+body+phantom+atom+phantom/pmc09875827-3335-10-15
Average 90 stars, based on 1 article reviews
3d point-cloud data (1280x720) of human body phantom atom phantom - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sun Nuclear Corporation echo-signal data phantom sono403
Echo Signal Data Phantom Sono403, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phantom+data/sono403/10__1177_slash_01617346221107728-116-6-8
Average 90 stars, based on 1 article reviews
echo-signal data phantom sono403 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results